Laerdal Aed Trainer 2 User Manual
- Laerdal SimPad User Manual. An operating device used to control laerdal manikins and simulators and can be used with task trainers and standardized patients/with skillreporter. AED Trainer 2 and AED Trainer 3 SkillReporter displays real time CPR feedback Enable this feature in BLS settings by selecting the AED Trainer type. After correct.
- The Laerdal AED Trainer 2 is 2015 Guidelines-compliant. To update the CPR prompts on your device, please access the AED Trainer software. On the main screen, under the CPR pause, please select CPR Prompt Short. For the programming software, please reference #94055.
- The Laerdal AED Trainer 2 is designed to prepare emergency responders to use the Heartstart FR2 AED. This Trainer. Provides a variety of simulations, or training scripts, to help responders become familiar with the AED and allow them to.
- Laerdal Aed Trainer 2 Pads
- Used Aed Trainer
- Aed Trainer Units
- Laerdal Aed Trainer 2 Manual
- Zoll Aed Plus Trainer 2 Manual
- Laerdal Download
2
Laerdal FR2 AED Trainer 2 Default Manufacturer The Laerdal AED Trainer 2 offers an affordable alternative for educating the layperson and healthcare provider in the effective use of an automatic external defibrillator. Simulates Philips FR2 clinical device.
IIN
NT
TE
EN
ND
DE
ED
D U
USSE
E
The Laerdal AED Trainer 2 is designed to prepare emergency responders to use the Heartstart FR2 AED. This Trainer
provides a variety of simulations, or training scripts, to help responders become familiar with the AED and allow them to
demonstrate the basic skills necessary to use the AED in an emergency.
NOTE: Before using the FR2 AED, the responder should have completed an appropriate responder training program, which may
include the use of the Laerdal AED Trainer 2. Having completed such a course, the responder should demonstrate a proficiency in
assessing the patient for lack of responsiveness, absence of breathing, and lack of circulation; cardiopulmonary resuscitation (CPR);
and knowledge of applicable medical protocols and procedures.
FFE
EA
AT
TU
UR
RE
ESS
-
The Laerdal AED Trainer 2 provides simulated shock delivery. It has no high-voltage capabilities, ensuring safety dur-
ing training. Important: Remember handling safety when using working defibrillators that give a high-voltage shock.
-
The Laerdal AED Trainer 2 is designed for use with the AED Little Anne and AED Resusci Anne manikins with
Laerdal Link Technology by giving responses to pad placement on the manikins. It can also be used with any other
manikin. Important: Realistic responses to pad placement feature is only available when used together with the AED Little
Anne or AED Resusci Anne manikins with Laerdal Link Technology.
-
The Laerdal AED Trainer 2 can be used with an optional infrared remote control. The remote control gives the
instructor the ability to control the training scenarios.
-
The Laerdal AED Trainer 2 is pre-configured with 10 training scenarios that simulate realistic sudden cardiac arrest
episodes. See page 6 for scenario descriptions. These scenarios are compatible with training programs developed
by nationally and internationally recognized responder programs. Check with your local medical director and
Emergency Medical System for additional training requirements, protocols, and materials. In addition, three custom
scenarios can be created using the optional Scenario Builder PC software. (See accessories on page 5).
-
The Laerdal AED Trainer 2 can be connected to the serial port of a PC (generally labeled 'COM1'). The optional
PC software lets you configure custom training scenarios, set-up various protocol parameters and change language
output. Connection to a PC serial port requires a standard 1:1 9-pin D-sub serial cable.
EE
NN
GG
LL
II
SS
HH
3
O
OV
VE
ER
RV
VIIE
EW
W
A
O
On
Laerdal Aed Trainer 2 Pads
n//O
Offff b
bu
utttto
on
n. Turns unit on and initiates voice prompts.
Press once to turn unit on. Press again to turn off.
B
P
Paad
dss C
Co
on
nn
ne
ecctto
orr SSo
occkke
ett. Insert the training pads
connector into the pads connector socket. The LED
flashes to indicate the socket location. The LED is covered
when the defibrillation pad connector is properly inserted
in the socket.
C
SSp
pe
eaakke
err. Provides audible instructions and information
about the unit and the patient's status. The speaker
volume can be controlled by the two blue Up / Down
buttons or the remote control. The last setting will be
stored and maintained even if the unit has been
turned off.
D
SSh
ho
occkk B
Bu
utttto
on
n. Controls simulated shock delivery. The button flashes when the unit is ready to deliver a
simulated shock.
E
U
Up
p//D
Do
ow
wn
n B
Bu
utttto
on
nss. Control the voice prompt volume during use. Important: These 'option' buttons
have different functions on the real automatic external defibrillators. Please refer to the FR2 AED User's Guide.
F
Used Aed Trainer
O
Op
pe
erraatto
orr D
Diissp
pllaayy aan
nd
d R
Re
mo
otte
e C
Co
on
nttrro
oll R
Re
ecce
eiivve
err. Indicates voice prompt volume, training scenario
selection, and responses to remote control inputs. (See the diagram and button description of the remote
control for examples of these indicators).
G
SSttaattu
uss W
Wiin
nd
do
ow
w. This window simulates the FR2 status display. By pulling on the tab you can switch
between the hour glass symbol and the X. For details of these symbols refer to your FR2 User's Guide.
H
B
Baatttte
erryy. The Laerdal AED Trainer 2 battery resembles that of the FR2 AED. Insertion and removal mechanisms
are similar. However, the Laerdal AED Trainer 2 battery case holds six (6) replaceable C-cell alkaline batteries.
Aed Trainer Units
I
T
Trraaiin
niin
ngg P
Paad
dss. Training pads resemble those used with the FR2, however
they do not deliver a shock. Training pads with a yellow connector are for
use with any manikin; those with a white connector and 'Laerdal Link
Technology' logo are for use with AED Little Anne and AED Resusci Anne
manikins with Laerdal Link Technology. NOTE: The Laerdal AED Trainer 2
comes with one set of training pads with a yellow connector. When the
yellow connector is inserted into the trainer's connector socket, the trainer
responds as if the pads are attached to a patient and proceeds through the
treatment protocol. The training pads are for training use only and will not
function with an actual FR2 AED.
J
R
Re
em
mo
otte
e C
Co
on
nttrro
oll ((o
op
pttiio
on
Laerdal Aed Trainer 2 Manual
naall)) The optional remote control can be used to control the different features of
the Laerdal AED Trainer 2 during training sessions (see accessories on page 5). Refer to the diagram below
with individual button functions described. Most remote control actions generate a red digital character
response in the operator display window on the Laerdal AED Trainer 2 device as shown in the table below.
A
H
D
C
Zoll Aed Plus Trainer 2 Manual
F
G
E
B