Mq Power Whisperwatt Dca45ssiu4f User Manual

  1. Mq Power Whisperwatt Parts
  2. Multiquip Dca45ssiu4f

WHISPERWATT™ SERIES MODEL DCA45SSIU4F 60Hz GENERATOR (ISUZU 4LE2X DIESEL ENGINE) Revision #4 (09/19/19) OPERATION MANUAL. Recommended by MQ Power for this equipment. Damage to the equipment and/or injury to user may result. PARTS AND OPERATION MANUAL MQ POWER DCA-25SSI WHISPERWATTTM GENERATOR PARTS LIST NO. MA FINAL COPY (06/29/01). Recommended by MQ Power for this equipment. Damage to the equipment and/or injury to user may result. Manufacturer does not assume responsibility for any. MQ Power ® Generators. Respected worldwide for their unsurpassed reliability, efficiency, and ultra-quiet performance. Multiquip is unmatched with a first-class line of generators fit for every application. MQ Power is the brand you can rely on when you need dependable power. Get Multiquip MQPower Whisperwatt Series DCA-300SSK Portable Generator User Manual. Get all Multiquip manuals! And efficient operation of the MQ Power Model DCA. OPERATION AND PARTS MANUAL MQ POWER DCA-70SSJU WHISPERWATTTM GENERATOR S/N 73 KEY START S/N 73 ECU/EGS. Efficient operation of the MQ Power Model DCA70SSJU Series WHISPERWATT™ GENERATOR. Before using this GENERATOR, ensure that the operating. The equipment and/or injury to user may result.

Advertising

dca45SSIU4F 60 hz generator• operatIon manUal — rev. #0 (09/09/14) — page 59

trOUbLeshOOtiNG DiaGNOstiC (LaMp)

The engine controller of this generator diagnoses problems

(faults/errors) that arise from the engine control system and

the engine itself.
When any engine faults occur during operation of the

generator the

warning lamp (diagnostic lamp) located on

the control panel will turn on. If this conditions occurs please

perform immediately the engine fault code diagnostic

procedure below.

engIne FaUlt code dIagnoStIc procedUre

1. Remove all loads from the generator and place all

circuit breakers in the

OFF position.

2. Stop the engine, release the retaing screws that secure

the control panel to the generator frame.

3. Next, slowly let the control panel fall forward so that

the control box is exposed.

4. To start the diagnostic process, place the

diagnostic

switch to the ON (Figure 59) position.

Figure 59. Diagnostic Panel

5. Verify that the

diagnostic lamp is ON. This indicates

that there is a fault/error in the engine or the engine

control system.

DIAGNOSTIC

LAMP

DIAGNOSTIC

BUTTON

DIAGNOSTIC

SWITCH

ON

OFF

FUEL PUMP

SWITCH

ON

NOTICE

Make sure to place the diagnostic switch back to

the

Feb 26, 2017  These pages introduce you to Macrium Reflect, its capabilities and methods. The first thing you should do is create rescue media. See The Macrium Rescue Environment. With your rescue media in-hand, we recommend that you follow through some basic tutorials to learn the system and to gain some immediate security by backing up your Systems. 23 rows  Protect your data, upgrade your hard disk or try new operating systems in the safe. Macrium reflect 7 free download. Macrium Reflect 7 User. If you have Macrium Reflect 7, the update to 7.2 is free. Just choose 'Check for updates' in the 'Other tasks' menu and it will download. Version 6 Home User. If you bought your v6 license on or after 26th November 2016, it is eligible for a free upgrade to v7.

OFF position after completing engine fault code

diagnostic procedures.

6. Push and hold the

diagnostic button to identify the

fault. and verify the following:

• Diagnostic lamp will start blinking with a pattern

according to the detected fault code 3 times at a interval

rate of 2.4 seconds.

• If two or more faults code are detected the diagnostic

lamp will repeat the detected fault codes blinking

pattern in ascending order. After all the detected fault

codes are shown, the process will repeat starting with

the first fault code.

• If no fault is detected the diagnostic lamp will blink

repeatedly at a interval rate of 2.4 seconds.

NOTICE

For a complete understanding of error codes and

troubleshooting procedures, refer to the enclosed

engine instruction manual.

NOTICE

The diagnostic lamp will indicate the current fault code

with the previous fault code in ascending order.
Also when a fault is detected the fault code will

automatically be saved as the previous code in the

ECM even after the fault has been repaired.

NOTICE

If a fault occurs while the engine is running the

2013 honda cr v user manual pdf

diagnostic lamp will turn on indicating only the current

fault. Please note that the fault code (blinking pattern)

cannot be shown while the engine is running.

Advertising
Popular Brands
Popular manuals
  • MQ Whisperwatt DCA45SSI Generator (40kW)

MQ Whisperwatt DCA45SSI Generator (40kW)

Please Call for Low Discount Pricing
DCA45SSIU4F
2,337.00 LBS


The MQ Power Whisperwatt DCA45SSIU4F mobile diesel generator offers up to 40 kW of single/three phase power at a quiet 66 dBA.

FEATURES

  • Designed and built to withstand tough environments at construction sites and provide dependable temporary power at entertainment venues and disaster recovery operations.
  • Voltage selector switch offers the operator a wide range of voltages that are manually selectable. Fine tuning of the output voltage can be accomplished by adjusting the voltage regulator control knob to obtain the desired voltage.
  • Automatic start/stop control — automatically starts the generator set during a commercial power failure when used in conjunction with a transfer switch.
  • ECU750 — automatic CANBUS engine control with LED status indicator lights.
  • Complete engine analog instrumentation includes DC ammeter, oil pressure gauge, water temp. gauge, fuel level gauge, tachometer/hour meter, preheat indicator, and emergency shutdown monitors.
  • Complete generator analog instrumentation includes voltage regulator control, ammeter phase selector switch, voltmeter phase selector switch, AC voltmeter, AC ammeter, frequency meter, panel light, and circuit breaker.
  • Automatic safety shutdown system monitors the water temperature, engine oil pressure, overspeed, and overcrank; warning lights indicate abnormal conditions.
  • Main line circuit breaker with 125A rating.
  • Complete power panel. Fully covered; three-phase terminals and single phase receptacles allow fast and convenient hookup for most applications including temporary power boxes, tools, and lighting equipment.
  • Brushless alternator reduces service and maintenance requirements and meets temperature rise standards for Class H insulation systems.
  • Open delta alternator design provides virtually unlimited excitation for maximum motor starting capability.
  • Automatic voltage regulator (AVR) provides precise regulation.
  • Electronic Governor Control — isochronous control, maintains frequency to within ±0.25% from no load to full load.
  • Full load acceptance of standby nameplate rating in one step (NFPA 110, para 5-13.2.6).
  • Heavy-duty, 4-cycle, direct injection, turbocharged, EGR, EPA Tier 4 Final certified, Isuzu diesel engine.
  • Fuel/water separator removes condensation from fuel for extended engine life. Panel mounted alarm light included.
  • Internal fuel tank with direct reading of fuel gauge.
  • Spill containment — Bunded design protects environment by capturing up to 119% of engine fluids.
  • Sound-attenuated, weather-resistant, steel housing.
  • E-coat and powder coat paint provides durability and weather protection.
  • Fully lockable enclosure allows safe unattended operation.

DOWNLOAD

TRAILER OPTIONS

  • TRLR45
  • TRLR75XF2 (with 100 gallon fuel cell; requires a mounting kit)

See Accessories Tab for further information.

OPTIONS (Order with Generator)

  • Audible Alarm
  • 3A Battery Charger
  • Battery Disconnect Switch
  • Camlock Connections (Single Set)
  • Cold Weather Block Heater
  • Emergency Stop Button
  • External Fuel Three-Way Manual Fuel Valve
  • External Fuel Three-Way Automatic Fuel Valve
  • Fire Extinguisher - 5 lbs. with bracket
  • Low Coolant Shutdown
  • Power Balance Kit (Brochure)
DCA45SSIU4F
40 kW / 50 kVA at 3PH, 28.8 kW at 1PH
36 kW / 45 kVA at 3PH, 26kW at 1PH
108A @ 240V, 54A @ 480V
100A (4 wire) / 108A x 2 (zigzag) @ 120V, 50A (4 wire) / 108A (zigzag) @ 240V
120/208, 127/220, 139/240V
240/416, 254/440, 277/480V
120/240V
0.5%
60 Hz / 0.25%
0.8
Star with neutral / Zigzag

Mq Power Whisperwatt Parts

4-pole, Revolving field, Self-ventilated, Drip-proof, Single bearing, Brushless with AVR, 1800 rpm
2 - 20A 120V GFCI Duplex (5-20), 3 - 50A 240V Twistlock (CS6369)
66 dBA

Multiquip Dca45ssiu4f

Isuzu 4LE2X, 4-cylinder, 4-cycle, Water-cooled, Direct Injection, Turbocharged, EGR
Electric
1 - 12V 72Ah
Diesel / 79.2 gallons
2.93 gph @ full load, 1.6 gph @ half load
EPA Tier 4 Final
84 x 38 x 62
2337 lb.
12 months / unlimited hours (or) 60 months / 5000 hours
24 months / 2000 hours

RELATED ITEMS

  • Steadypower 400A Generator Cable Set (5 Cables)$934.00

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!